SBA Service-Disabled Veteran-Owned Certified

Water Treatment Glossary

This glossary explains the words you see on a water test report, a utility water-quality report and a treatment quote, in plain English. Each entry links to the Water Pros page that goes deeper, and our free local basic test covers hardness, iron and pH.

Action level
A trigger level for lead and copper in a utility system. If more than 10 percent of samples are above it, the utility has to take steps. The action level for lead is 0.015 mg/L, moving to 0.010 mg/L from November 1, 2027.
Activated carbon
A porous media that takes out chlorine, taste and odor. See charcoal filtration.
Arsenic
A naturally occurring element found in some Northern Nevada ground water. The federal limit is 10 ppb. See arsenic filtration.
Arsenic III and arsenic V
Two chemical forms of arsenic. Arsenic V is generally easier to remove, and a lab can report which form is present, which helps us choose treatment.
Backwash
A reverse flow of water through a filter bed that lifts the media and flushes trapped particles to the drain. Most iron filters backwash on a timer or by water use.
Big Blue filter
A full-size filter housing used for whole-house sediment and carbon filtration.
Birm
A filter media used for iron removal that works with air or dissolved oxygen in the water. It suits water in a favorable pH range.
Brine tank
The salt tank beside a softener. Water dissolves the salt into brine, which the softener draws during regeneration. See how often to add salt.
Calcite
A mineral media used to raise low pH. The water dissolves it slowly and the pH rises. See pH adjustment.
CCR (consumer confidence report)
The annual water quality report every public water system mails or posts. Reading your CCR is the first step on city water, and our guide how to read a water test report explains the layout.
Certified lab test
A laboratory analysis by a lab certified by the State of Nevada. It is typically required for well water and for a home sale, and it measures items like arsenic, nitrate, uranium and bacteria. See well water testing.
Chlorine injection
A pump that feeds a measured dose of chlorine solution into well water to treat iron, sulfur smell and bacteria. See chlorine injection systems.
Chlorine residual
The small amount of chlorine left in city water to keep it safe through the pipes. Carbon filters remove it for taste.
Contact tank
A tank that holds water after chlorine injection so the chlorine has time to work before filtration.
Domestic well
A private well that serves a single home. The owner is responsible for its water quality.
Flat-rate service call fee
The way we charge for service calls, with no hourly labor charges and no fuel surcharges.
Free local basic test
Our free local test for hardness, iron and pH. You do not have to be an existing customer. See water testing.
Grains per gallon (gpg)
The unit most softeners use to measure hardness. One grain per gallon equals 17.1 mg/L as calcium carbonate, which is how we convert a lab number into the figure a water softener is sized on.
Greensand
A filter media that helps oxidize dissolved iron and manganese and then filters out the particles. See greensand filters.
Gross alpha
A lab screen for radioactivity from alpha particles. The federal limit of 15 pCi/L applies after radon and uranium are subtracted; uranium has its own limit of 30 ug/L.
Hardness
The amount of dissolved calcium and magnesium in water. USGS describes 0 to 60 mg/L as soft, 61 to 120 as moderately hard, 121 to 180 as hard and over 180 as very hard. See hardness by town.
Holding tank
The small pressurized tank under the sink that stores treated RO water so the faucet fills at normal speed.
Hydrogen sulfide
The gas that gives water a rotten-egg smell. See sulfur filtration and rotten egg smell.
Ion exchange
The process a water softener uses. Water passes over resin beads that hold sodium or potassium and swap them for calcium and magnesium, which cling to the beads. See water softeners.
Iron
A metal that causes orange stains and a metallic taste. The EPA secondary guideline is 0.3 mg/L. See iron filtration.
Iron bacteria
Bacteria that feed on iron and can leave a slimy, rust-colored film. See iron bacteria in well water.
Locational running annual average
A running average calculated for one sampling location. Some contaminants are tracked this way, and it is why a utility report may list several results for the same item.
Maintenance plan
A scheduled service arrangement that covers filter changes, injector cleaning and checks of your equipment. See system maintenance.
Manganese
A metal that stains fixtures and laundry black or brown. The EPA secondary guideline is 0.05 mg/L. See manganese filtration.
MangOX, Filox and Pyrolox
Other oxidizing filter media used for iron and manganese. We choose among them after a test of iron, manganese and pH. See iron filtration.
MCL (maximum contaminant level)
The highest level of a contaminant the EPA allows in public drinking water. MCLs are enforceable for utilities and are a useful yardstick for a private well, which has no one enforcing them.
mg/L
Milligrams per liter, a measure of how much of a substance is dissolved in water. It is equal to parts per million (ppm) for water in practical terms.
Micrograms per liter (ug/L)
A unit used for very small amounts, the same as ppb. Uranium and arsenic limits are written in this unit.
Micron
A unit of particle size. A 5 micron filter catches particles that size and larger, and the number helps pick the right cartridge.
Nitrate
A form of nitrogen found in some wells. The federal limit is 10 mg/L as nitrogen, and it is measured by a certified lab. See nitrate filtration.
Oxidizer
A chemical or process, such as chlorine, air or permanganate, that converts dissolved iron, manganese and hydrogen sulfide into particles that can be filtered out.
pCi/L
Picocuries per liter, the unit that measures radioactivity in water. Radon, radium and alpha particles are all reported this way.
Permeate
The treated water that passes through an RO membrane. The water that carries away the rejected minerals goes to the drain.
pH
A scale from 0 to 14 that tells how acidic or basic water is. The EPA secondary range is 6.5 to 8.5, and pH affects pipes and which filter media works.
Point of entry (POE)
Treatment where water enters the house, such as a whole-house filter or softener. See whole-house filtration.
Point of use (POU)
Treatment at a single tap, such as an under-sink RO system for drinking water.
Potassium chloride
A salt alternative that some softeners use in place of sodium chloride. Our guide on sodium vs. potassium salt covers how to choose.
Potassium permanganate
A purple chemical used to recharge greensand media. It is drawn from a small tank during regeneration.
ppb
Parts per billion, which is a thousand times smaller than ppm. Arsenic is reported this way: the federal limit of 10 ppb equals 0.010 mg/L, or 10 micrograms per liter.
ppm
Parts per million. One ppm is one part of a substance in a million parts of water, and it matches mg/L on a lab report.
Primary standard
A health-based drinking water standard, such as the arsenic, nitrate and uranium limits. A certified lab test is how you measure these.
Public water system
A utility that serves many customers and is regulated and tested under the federal Safe Drinking Water Act. A private well is not part of one.
Radon
A radioactive gas that can dissolve in ground water. There is no federal limit for radon in water. See radon gas filtration.
Regeneration
The recharge cycle for a softener or a greensand filter. A softener flushes brine through its resin; a greensand filter is recharged with potassium permanganate.
Resin
The tiny beads inside a softener tank that do the ion exchange. The beads are recharged by regeneration and last for years with the right maintenance.
Reverse osmosis (RO)
A membrane process that holds back most dissolved salts and minerals, usually at one tap. See reverse osmosis systems.
RO membrane
The thin sheet at the heart of a reverse osmosis system that lets water through while holding back most dissolved solids.
Routine Domestic Panel
A common private-well lab panel, also called a Routine Domestic Analysis or an Escrow Package. Well owners order it for their own information or when a lender asks for it during a home sale.
Running annual average (RAA)
The average of the samples taken over a year. Utilities are judged on this average rather than on one sample, so a single high reading does not by itself mean a violation.
Salt-free conditioner
A device that changes how scale forms rather than removing hardness minerals. Our guide on softener vs. salt-free conditioner compares the two.
Scale
The white, chalky buildup that hard water leaves on faucets, heating elements and inside pipes. Our page on white spots and scale covers causes and fixes.
Secondary standard
A guideline for taste, color, odor and staining rather than health, such as 0.3 mg/L for iron and 0.05 mg/L for manganese. The EPA does not enforce these federally.
Sediment
Sand, silt, rust and other particles carried in water. A sediment filter catches them. See sediment filtration.
Sulfate
A dissolved mineral that can give water a bitter or salty taste. The EPA secondary guideline is 250 mg/L. See sulfate filtration.
Total coliform
A group of bacteria used as a sign that a well may be open to contamination. University of Nevada Cooperative Extension advises a test every year.
Total dissolved solids (TDS)
The total of all dissolved minerals and salts in water, measured in mg/L. The EPA secondary guideline is 500 mg/L, and reverse osmosis is the usual way to lower it at the tap. See TDS filtration.
Uranium
A naturally occurring element in some ground water, with a federal limit of 30 ug/L. See uranium in Nevada well water.
UV (ultraviolet) disinfection
A light that disinfects water by treating bacteria as it passes. See bacteria filtration.
Water test report
A lab's written results, listing each item tested, the amount found and the limit. We read these with you line by line and match each result to a fix.
Sources (4)

Offering you the quality Water Treatment Services you deserve!

Free local basic testing to include hardness, iron & pH. Service on most water treatment systems, even ones we did not install.

or call 775-674-2871

★★★★★ 4.9 on Google from 55 reviews

Monday - Friday - 8am to 4:30pm

Get in Touch