- Action level
- A trigger level for lead and copper in a utility system. If more than 10 percent of samples are above it, the utility has to take steps. The action level for lead is 0.015 mg/L, moving to 0.010 mg/L from November 1, 2027.
- Activated carbon
- A porous media that takes out chlorine, taste and odor. See charcoal filtration.
- Arsenic
- A naturally occurring element found in some Northern Nevada ground water. The federal limit is 10 ppb. See arsenic filtration.
- Arsenic III and arsenic V
- Two chemical forms of arsenic. Arsenic V is generally easier to remove, and a lab can report which form is present, which helps us choose treatment.
- Backwash
- A reverse flow of water through a filter bed that lifts the media and flushes trapped particles to the drain. Most iron filters backwash on a timer or by water use.
- Big Blue filter
- A full-size filter housing used for whole-house sediment and carbon filtration.
- Birm
- A filter media used for iron removal that works with air or dissolved oxygen in the water. It suits water in a favorable pH range.
- Brine tank
- The salt tank beside a softener. Water dissolves the salt into brine, which the softener draws during regeneration. See how often to add salt.
- Calcite
- A mineral media used to raise low pH. The water dissolves it slowly and the pH rises. See pH adjustment.
- CCR (consumer confidence report)
- The annual water quality report every public water system mails or posts. Reading your CCR is the first step on city water, and our guide how to read a water test report explains the layout.
- Certified lab test
- A laboratory analysis by a lab certified by the State of Nevada. It is typically required for well water and for a home sale, and it measures items like arsenic, nitrate, uranium and bacteria. See well water testing.
- Chlorine injection
- A pump that feeds a measured dose of chlorine solution into well water to treat iron, sulfur smell and bacteria. See chlorine injection systems.
- Chlorine residual
- The small amount of chlorine left in city water to keep it safe through the pipes. Carbon filters remove it for taste.
- Contact tank
- A tank that holds water after chlorine injection so the chlorine has time to work before filtration.
- Domestic well
- A private well that serves a single home. The owner is responsible for its water quality.
- Flat-rate service call fee
- The way we charge for service calls, with no hourly labor charges and no fuel surcharges.
- Free local basic test
- Our free local test for hardness, iron and pH. You do not have to be an existing customer. See water testing.
- Grains per gallon (gpg)
- The unit most softeners use to measure hardness. One grain per gallon equals 17.1 mg/L as calcium carbonate, which is how we convert a lab number into the figure a water softener is sized on.
- Greensand
- A filter media that helps oxidize dissolved iron and manganese and then filters out the particles. See greensand filters.
- Gross alpha
- A lab screen for radioactivity from alpha particles. The federal limit of 15 pCi/L applies after radon and uranium are subtracted; uranium has its own limit of 30 ug/L.
- Hardness
- The amount of dissolved calcium and magnesium in water. USGS describes 0 to 60 mg/L as soft, 61 to 120 as moderately hard, 121 to 180 as hard and over 180 as very hard. See hardness by town.
- Holding tank
- The small pressurized tank under the sink that stores treated RO water so the faucet fills at normal speed.
- Hydrogen sulfide
- The gas that gives water a rotten-egg smell. See sulfur filtration and rotten egg smell.
- Ion exchange
- The process a water softener uses. Water passes over resin beads that hold sodium or potassium and swap them for calcium and magnesium, which cling to the beads. See water softeners.
- Iron
- A metal that causes orange stains and a metallic taste. The EPA secondary guideline is 0.3 mg/L. See iron filtration.
- Iron bacteria
- Bacteria that feed on iron and can leave a slimy, rust-colored film. See iron bacteria in well water.
- Locational running annual average
- A running average calculated for one sampling location. Some contaminants are tracked this way, and it is why a utility report may list several results for the same item.
- Maintenance plan
- A scheduled service arrangement that covers filter changes, injector cleaning and checks of your equipment. See system maintenance.
- Manganese
- A metal that stains fixtures and laundry black or brown. The EPA secondary guideline is 0.05 mg/L. See manganese filtration.
- MangOX, Filox and Pyrolox
- Other oxidizing filter media used for iron and manganese. We choose among them after a test of iron, manganese and pH. See iron filtration.
- MCL (maximum contaminant level)
- The highest level of a contaminant the EPA allows in public drinking water. MCLs are enforceable for utilities and are a useful yardstick for a private well, which has no one enforcing them.
- mg/L
- Milligrams per liter, a measure of how much of a substance is dissolved in water. It is equal to parts per million (ppm) for water in practical terms.
- Micrograms per liter (ug/L)
- A unit used for very small amounts, the same as ppb. Uranium and arsenic limits are written in this unit.
- Micron
- A unit of particle size. A 5 micron filter catches particles that size and larger, and the number helps pick the right cartridge.
- Nitrate
- A form of nitrogen found in some wells. The federal limit is 10 mg/L as nitrogen, and it is measured by a certified lab. See nitrate filtration.
- Oxidizer
- A chemical or process, such as chlorine, air or permanganate, that converts dissolved iron, manganese and hydrogen sulfide into particles that can be filtered out.
- pCi/L
- Picocuries per liter, the unit that measures radioactivity in water. Radon, radium and alpha particles are all reported this way.
- Permeate
- The treated water that passes through an RO membrane. The water that carries away the rejected minerals goes to the drain.
- pH
- A scale from 0 to 14 that tells how acidic or basic water is. The EPA secondary range is 6.5 to 8.5, and pH affects pipes and which filter media works.
- Point of entry (POE)
- Treatment where water enters the house, such as a whole-house filter or softener. See whole-house filtration.
- Point of use (POU)
- Treatment at a single tap, such as an under-sink RO system for drinking water.
- Potassium chloride
- A salt alternative that some softeners use in place of sodium chloride. Our guide on sodium vs. potassium salt covers how to choose.
- Potassium permanganate
- A purple chemical used to recharge greensand media. It is drawn from a small tank during regeneration.
- ppb
- Parts per billion, which is a thousand times smaller than ppm. Arsenic is reported this way: the federal limit of 10 ppb equals 0.010 mg/L, or 10 micrograms per liter.
- ppm
- Parts per million. One ppm is one part of a substance in a million parts of water, and it matches mg/L on a lab report.
- Primary standard
- A health-based drinking water standard, such as the arsenic, nitrate and uranium limits. A certified lab test is how you measure these.
- Public water system
- A utility that serves many customers and is regulated and tested under the federal Safe Drinking Water Act. A private well is not part of one.
- Radon
- A radioactive gas that can dissolve in ground water. There is no federal limit for radon in water. See radon gas filtration.
- Regeneration
- The recharge cycle for a softener or a greensand filter. A softener flushes brine through its resin; a greensand filter is recharged with potassium permanganate.
- Resin
- The tiny beads inside a softener tank that do the ion exchange. The beads are recharged by regeneration and last for years with the right maintenance.
- Reverse osmosis (RO)
- A membrane process that holds back most dissolved salts and minerals, usually at one tap. See reverse osmosis systems.
- RO membrane
- The thin sheet at the heart of a reverse osmosis system that lets water through while holding back most dissolved solids.
- Routine Domestic Panel
- A common private-well lab panel, also called a Routine Domestic Analysis or an Escrow Package. Well owners order it for their own information or when a lender asks for it during a home sale.
- Running annual average (RAA)
- The average of the samples taken over a year. Utilities are judged on this average rather than on one sample, so a single high reading does not by itself mean a violation.
- Salt-free conditioner
- A device that changes how scale forms rather than removing hardness minerals. Our guide on softener vs. salt-free conditioner compares the two.
- Scale
- The white, chalky buildup that hard water leaves on faucets, heating elements and inside pipes. Our page on white spots and scale covers causes and fixes.
- Secondary standard
- A guideline for taste, color, odor and staining rather than health, such as 0.3 mg/L for iron and 0.05 mg/L for manganese. The EPA does not enforce these federally.
- Sediment
- Sand, silt, rust and other particles carried in water. A sediment filter catches them. See sediment filtration.
- Sulfate
- A dissolved mineral that can give water a bitter or salty taste. The EPA secondary guideline is 250 mg/L. See sulfate filtration.
- Total coliform
- A group of bacteria used as a sign that a well may be open to contamination. University of Nevada Cooperative Extension advises a test every year.
- Total dissolved solids (TDS)
- The total of all dissolved minerals and salts in water, measured in mg/L. The EPA secondary guideline is 500 mg/L, and reverse osmosis is the usual way to lower it at the tap. See TDS filtration.
- Uranium
- A naturally occurring element in some ground water, with a federal limit of 30 ug/L. See uranium in Nevada well water.
- UV (ultraviolet) disinfection
- A light that disinfects water by treating bacteria as it passes. See bacteria filtration.
- Water test report
- A lab's written results, listing each item tested, the amount found and the limit. We read these with you line by line and match each result to a fix.
Sources (4)
- U.S. EPA: epa.gov/ground-water-and-drinking-water/national-primary-drinking-water-regulations (checked November 2026)
- U.S. EPA: epa.gov/sdwa/secondary-drinking-water-standards-guidance-nuisance-chemicals (checked November 2026)
- U.S. Geological Survey: usgs.gov/special-topics/water-science-school/science/hardness-water (checked November 2026)